Product 1: Air-Source Small & Medium Ozone Generator Parameters
| Model | Ozone Output (g/h) | Air Flow (Nm³/h) | Cooling Water Flow (m³/h) | Power Consumption (Kwh/kgO3) | Dimensions (mm) |
|---|---|---|---|---|---|
| MH-D-K100 | 100 | 3.3-5.0 | 0.4-0.5 | 1.1-1.4 | 1200×600×1750 |
| MH-D-K200 | 200 | 6.5-10.0 | 0.8-1.0 | 2.2-2.7 | 1200×600×1750 |
| MH-D-K300 | 300 | 10.5-15.0 | 1.2-1.5 | 3.4-4.0 | 1200×600×1750 |
| MH-D-K500 | 500 | 16.0-25.0 | 2.0-2.5 | 5.6-6.8 | 1600×600×1950 |
| MH-D-K600 | 600 | 20.0-30.0 | 2.4-3.0 | 6.7-8.2 | 1800×800×1950 |
| MH-D-K800 | 800 | 26.6-40.0 | 3.2-4.0 | 9.0-10.9 | 1800×800×1950 |
| MH-D-K1000 | 1000 | 33.4-50.0 | 4.0-5.0 | 11.2-13.6 | 1800×800×1950 |
Product 2: Oxygen-Source Small & Medium Ozone Generator Parameter Table
| Model | Ozone Output (g/h) | Air Flow (Nm³/h) | Cooling Water Flow (m³/h) | Power Consumption (Kwh/kgO3) | Dimensions (mm) |
|---|---|---|---|---|---|
| MH-D-F100 | 100 | 0.7-1.0 | 0.2-0.3 | 0.7-0.9 | 1200×600×1750 |
| MH-D-F200 | 200 | 1.4-2.0 | 0.2-0.4 | 1.4-1.8 | 1200×600×1750 |
| MH-D-F300 | 300 | 2.0-3.0 | 0.3-0.6 | 2.1-2.7 | 1200×600×1750 |
| MH-D-F500 | 500 | 3.4-5.0 | 0.5-1.0 | 3.5-4.5 | 1200×600×1750 |
| MH-D-F600 | 600 | 4.0-6.0 | 0.6-1.2 | 4.2-5.4 | 1400×600×1750 |
| MH-D-F800 | 800 | 5.4-8.0 | 0.8-1.6 | 5.6-7.2 | 1600×800×1950 |
| MH-D-F1000 | 1000 | 6.7-10.0 | 1.0-2.0 | 7.0-9.0 | 1600×800×1950 |
Notes:
1. Power consumption varies based on ozone concentration and operating conditions (cooling water and feed gas temperatures).
2. The data in this table is for reference only.
FAQ
Q1: What are the advantages of ozone over conventional chemical dosing?
Ozone provides rapid decolorization, powerful oxidation of refractory organics, and complete disinfection without chemical residues or secondary sludge. It reduces chemical storage and sludge disposal costs, making it ideal for strict wastewater upgrading and reuse standards.
Q2: How to fix poor ozone performance or low decolorization efficiency?
Subpar performance typically stems from insufficient ozone output concentration, poor gas-liquid mixing, or inadequate contact reaction time. Quick fix: Adjust generator ozone production settings, inspect Venturi injectors or micro-bubble diffusers for uniform mixing, and extend hydraulic retention time in the contact chamber.
Q3: Do you offer water-cooled, air-cooled, and fully automated ozone models?
Yes. We provide both air-cooled units (ideal for compact, lower-capacity setups) and heavy-duty water-cooled generators (designed for high-capacity industrial applications). All systems feature intelligent PLC automation,supporting automated start/stop, concentration regulation, and scheduled cycle operations.




Henan Public Network Security Registration No. 41077102000244